STEP 2: Release the mechanical lock by
turning Key - F - to the horizontal position.
P RO C E D U R E F OR I N S TA L L AT I O N ( c on t . )
STEP 1: Remove the cover - E - by
removing 4 screws.
STEP 3:
Position and level the operator brackets
and plates (SEE BELOW AND PAGE 3). Tack
weld plate and brackets in position.
F
With gate closed, position the plates on the gate taking care that the operator is
kept level.
I M P O RTA N T: Weld front bracket at the top of the bar so operator will not hit
bar while traveling.